con edison s 596
Why are contractors frustrated with Con Edison?
During interviews, some contractors expressed frustration related to what they see as a lack of clarity from Con Edison regarding the calculations and documentation required for custom applications. This is particularly problematic for newer technologies.
Do PCs want to be part of the Con Edison team?
PCs want to be considered part of the Con Edison team through consistent notifications about program changes and activity as well as recognition for their work. Increased communications promoting the current benefits of participating can help bolster program activity. Twelve contractors reported noticing changes related to the program implementer.
Does Con Edison have a large C&I program?
Large Commercial & Industrial (Large C&I) Program Impact and Process Evaluation In 2017, Con Edison started implementing the Large C&I program in-house to increase customer satisfaction. The program had nearly 600 participants and reported 86 GWh, 15 MW, and 826,539 therms saved in 2017.
Does Con Edison have internal guidance documents?
Sources: Con Edison 2017-2018 CI Program Process Improvement Memo_Final; Program Staff Interviews (Con Edison 2017-2018 CI Program Staff Interview Memo_Final) and informal discussions. Internal guidance documents (desk guides) exist for operations, engineering, inspections, and QA/QC teams, but not for the BD and marketing teams.
System Design
Con Edison undertook this repowering project in 2001 to ensure that the company’s steam system-the largest in the world-would continue to provide the environmental benefits of steam service year-round and to provide a new source of electric generation to New York City. The East River Station facility was selected because it had the needed space and
Water Treatment Process
The raw water feed to the water treatment system is supplied by the raw water pumps that take suction from an 80,000-gallon raw water storage tank. Before it reaches the multi-media filters, the raw water passes through heat exchangers to provide a heat-sink for the units’ closed cooling loops. This results in seasonally varying supply temperatures
Construction
One of the most unique aspects of the repowering project was the challenge of fitting two combined cycle units and their associated auxiliary systems into an existing structure. In terms of the water treatment system, two major aspects of equipment siting are particularly interesting: the location and construction of the main process equipment and
Operating Results
Commissioning of the water treatment system began in early 2005 and commercial operation began in April of that year. The system was designed to be run by one operator with 24-hour coverage; however the equivalent of a second operator is often required during cleaning periods. Table 4 summarizes the typical RO/CEDI system performance for the period
Recent Modifications
Additional maintenance has been performed on this water purification system. RO membranes were replaced in January and February 2007 due to an increase in salt passage. At about the same time, increased CEDI module electrical resistance led to a chemical cleaning of the CEDI system. An alkaline brine solution was found to be most effective for rest
References
(1) Gifford, J. and Atnoor, D. An Innovative Approach to Continuous Electrodeionization Module and System Design for Power Applications, International Water Conference, Paper IWC-00-52, October 2000. (2) Wood, J., Westberg, E. and Blackbourn, D., Field Experience with a New CEDI Module Design, International Water Conference, Paper IWC-03-37, Octobe
Untitled
20 janv. 2006 OPERATED BALL-TYPE METER REG. VALVES. SHEET 1 OF 2. CONSOLIDATED EDISON COMPANY OF N.Y.. STEAM ENGINEERING DEPT. S-596. |
\Steamsv1DATADIRSENGINEERMeteringMetering Specs
20 janv. 2006 S6S-S. REVISIONS. 09/11/89. CON EDISON ... METER AND BALL VALVE SHALL BE MOUNTED WITH MOTOR. OPERATOR AT 3 O'CLOCK OR 9 O'CLOCK POSITION. |
Untitled
25 oct. 1974 5-2-85 6. Mohegra. CHGD TITLE |
Specification EO-6224
30 sept. 2017 1967-2017 Consolidated Edison Co. of New York Inc. Paper copies of procedures and instructions are uncontrolled and therefore may be ... |
Plot of C:Documents and SettingsohkDesktopS-00591-5 Meter
1 juil. 1998 6. 8. 10. 12. 16. STRAIGHTENING VANE WITH FLANGE ... (SUPPLIED BY CON EDISON) ... S-596 AND S-625 WHEN STRAIGHTENING. VANES ARE USED. |
Specification EO-14608-B
15 avr. 1985 ·CON EDISON CABLES ... SHALL BE CONNECTED BY THE CUSTOMER AND "EDISON" CABLES BY THE CONSOLIDATED EDISON CQ OF ... AS REGID EO-5022 596-2832. |
Etude nationale sur les programmes de francais de base: Le
ED 338 024. FL 019 596 applicability in Core French classes in Canadian elementary and ... one for Con: French program administrators and the other ... |
General Specification for the Installation of Gas Distribution Services
29 sept. 2017 4.10 If contaminated soil is discovered off Con Edison property follow EH&S GEHSI ... relocated or phenolic board (Class/Stock #596-4473 |
REGION DE LEST LYONNAIS APERÇU GEOLOGIQUE DAPRES
79 SGN 596 RHA 2°) s'efforcer de tirer parti des données géologiques apportées par une soixan ... la base ; le rapport de J. DESROUSSEAUX au con-. |
General Specification for the Installation of Gas Distribution Services
7 févr. 2020 4.11 If contaminated soil is discovered off Con Edison property ... shall be relocated or phenolic board (Class/Stock #596-4473 |
Typical Piping Installation of a Three Meter - Con Edison
20 jan 2006 · CONSOLIDATED EDISON COMPANY OF N Y , INC S-596 NOTE TYPICAL INSTALLATION OF THREE VORTEX STEAM METERS |
Steamsv1\DATADIRS\ENGINEER\Metering\Metering - Con Edison
20 jan 2006 · STEAM METER – SEE NOTES (a) (b) (k) (n) (p) (a) METER STOP VALVE GATE TYPE, C S , FLANGED, CLASS 300, RISING STEM |
Table of - Annual Reports
16 fév 2006 · a key component of Con Edison's strategy is an ongoing focus on the 596 860 Operating income 1,158 931 1,044 1,078 1,141 |